Lab

Series RLC Resonance: AC Sweep and Phase Lab

Two series RLC branches, 10 mH and 10 µF with 10 Ω or 100 Ω, resonate at 503 Hz. The AC sweep shows a sharp and a broad peak; Time Domain shows the phase.

Preview of Series RLC Resonance: AC Sweep and Phase Lab
Open in the lab Embed Run the circuit right here. To edit it in the full lab, sign in; free accounts have a time limit there.

Use this circuit in class: Series RLC circuit lab: resonance, bandwidth and phase

Teaching with circuits?

Create a classroom, give your students a circuit to build, and review what they submit. Try it free with one classroom and up to 5 students.

Try the free classroom demo

How it works

An inductor and a capacitor in series cancel each other at one frequency, f0 = 1/(2π√(LC)): with 10 mH and 10 µF it is 503.3 Hz. There the current is largest and the whole source voltage appears across the resistor.

A 10 V peak sine source drives two branches, each a 10 mH inductor, a 10 µF capacitor and a resistor: 10 Ω (N3) and 100 Ω (N5). The NGSpice chart opens on Time Domain at 250 Hz with N1 and N3: N3 is small and leads the source. Set Analysis Type to AC Sweep and add N3 and N5: both peak at 501 Hz, the 10 Ω branch sharply and the 100 Ω branch broadly.

What's inside

  • 1× Power Source
  • 2× Resistor (10 Ω, 100 Ω)
  • 2× Capacitor
  • 2× Inductor (1 H)

Tags

About

By Samir Sabri
Saved November 26, 2026
11 views
Page: dcaclab.com/circuits/88228-series-rlc-resonance-ac-sweep-and-phase-lab

Embed this circuit

<iframe src="https://dcaclab.com/experiments/88228-series-rlc-resonance-ac-sweep-and-phase-lab/iframe" width="560" height="410" frameborder="0"></iframe>

Cite: Sabri, S. (2026). Series RLC Resonance: AC Sweep and Phase Lab. DCACLab. https://dcaclab.com/circuits/88228-series-rlc-resonance-ac-sweep-and-phase-lab